← All sections of PWD Maharashtra SSR 2022-23
| Code | Description | Unit | Rate |
|---|---|---|---|
| 50.06 | Providing and applying two coats of protective membrane over the cured concrete surface like R.C.C. footings, columns, plinth beams etc. which will be submerged under soil so as to protect the same. Apply two pack coal tar epoxy system of Sunepoxy Coaltar of approved make & approved by Engineer in charge, having solid content ranges from 80- 100%, Tackfreetime4-6hrs.Recoat after16-24 hrs. Mix Part AandPart Bof Sunepoxy Coaltar of approved make & approved byEngineer in charge in 1:1 ratio with slow speed stirrer and applythe same on a clean R.C.C. surface bybrush. Allow to set for 8-10 hours and apply the second coat. The rate to include for application at all levels to various RCC elements to the satisfaction of the EIC etc. complete. | sqm | ₹ 247 |
| 50.07 | Providing & Supplying corrosion inhibiting admixture in concrete to protect steel bars for all concrete in every part Polyalk CP 293 of approved make & approved by Engineer in charge migrating, non-nitrite based corrosion inhibiting admixture shall be added at a dose of 3 Kilograms per cum of concrete. The admixture should protect both cathodic and anodic sites and havebeen accredited byIndianRoads Congress, recommended foruse by Ministry of Road Transport & Highways and should have a 4 year track record of use in both the Gulf Region and India. Admixture should have evaluated test reports demonstrating a corrosion rate of zero coulombs after 9 test cycles as per ASTM G 109 when tested from a research institution NBA accredited Grade A and internationally ranked among top 5 research institutions in the world in Annual Survey conducted by Georgia Institute of Technology ranking of research institutions. PH of admixture should bealkalineinnature,specificgravityof0.99–1.1,colour:brownish. Thecontractor must intimatetheengineerinchargepriortoaddition inconcreteforrecording.Ifthe admixture is put in the concrete mix at the batching plant, a written record of the amount of admixture used shall be supplied to the engineer. The engineer must ensure that the specified dosage of admixture is added in the concrete mix. (Material Cost Analysis only) | kg | ₹ 210 |
| 50.08 | Providing and mixing shrinkage compensating admixture cum plasticizer – Sunplex 330 gms pouch of approved make & approved by Engineer in charge, adding per 50Kilogrambag of cement in sand faced cement plaster to internal/external surfaces in finished in proper line and level. Add Sunplex in dry machine mix before addition of gauging water. (Material Cost Analysis only) | One Pouch | ₹ 42 |
| 50.09 | Providing and applying one pack bonding coat between concrete members like RCC slabs, columns,beams, chajjas, pardis etcand cement mortar plasterusing HackAid Plast of approved make & approved by Engineer in charge. Clean the concrete surface thoroughly to remove dust, dirt, grime, deshuttering oils and rub down to a clean surface. Apply Hack Aid Plast of approved make & approved by Engineer in charge byspray on the entire concrete surface. Provide a lean cement - sand dash coat over the same. Allow the dash coat to set for around 24 hours. Further plastering as per specifications can continue. | sqm | ₹ 54 |
| 50.10 | Clean the surface to remove dirt, loose particles. Examine the surface closely for any cracks. Clean the cracks. Provide and fill a pure acrylic, polymer modified ready to use paste Polyfill AR of approved make & approved by Engineer in charge having a cream coloured viscous emulsion readyto use acrylic polymeric non-shrink crackfillerputtywith auto suction properties and requiring no bonding agent, no curing and no requirement for opening the existing cracks finishing with subsequent filling as required. Provide and apply three coats of 100% acrylic waterproof heat insulating breathable decorative external coating Sunext 8 of approved make & approved by Engineer in charge, in the desired shade. Stir well and apply by brush for three coats. Applying three coats at an interval of 4-6 hours between each coat. High Performance 100% Acrylic, Waterproof, Anti-fungal, Anti-carbonation, Heat Insulating External Paint should have following minimum properties: 1. Specific Gravity: 1.3 ± 0.1 at 25°C 2. pH: 7.0 to 10.00 3. Viscosity: 18 to 30 sec. at 25°C by Ford Cup One Number B-4 (Dilute 2 parts of product with 1 part of water) 4. CO2 diffusion resistance co- efficient (DIN EN 1062-6 (2002-10): 7.59 x105 5. CO2 diffusion equivalent air layer thickness (DIN EN 1062-6 (2002-10): 127m @ 190 microns DFT 6. Adhesion (ASTM D 4541): 2.3 N/mm2 (Concrete / Substrate Failure) 7. Solar Reflectance Index (ASTM E 1980 11,EN 673:2011, EN 410:2011): 107 It shall be applied as per manufacturers specification. (cid:10) | sqm | ₹ 251 |
| 50.11 | Providing and fixing factory made door/Window frames of required colour made with wood Polymer composite (WPC) extuded internal ribbed sections conforming to American Society for testing and materials (ASTM) in regard with density, tensile strength, flexural strength, Izod impact, water absorption and screw withdrawal strength with wall thickness of 5mm (+/1mm) and with frames having mitred joints at each corner, joined together by two nos. of 10 x 8 mm & 40 mm long PVC dovetail keys including hardwood piecesupport alongthefullverticalandhorizontallengthin rebateportion hole for fixing hinges and fixtures and the frames fixed to Walls/columns with 15 mm long dash fasteners/holdfasts (dash fasteners/holdfasts to be paid separately) etc. complete as per the direction of Engineer in charge,with prior approval of concerned Superitending Engineer. | ||
| 50.11a | 1.1. For Profile size of 75 x 50 mm with 32 x 12 mm rebate | rmt | ₹ 435 |
| 50.11b | 1.2 For Profile size of 100 x 50 mm with 32 x 12 mm rebate | rmt | ₹ 535 |
| 50.11c | 1.3 For Profile size of 125 x 50 mm with 38 x 12 mm rebate | rmt | ₹ 635 |
| 50.11d | 1.4 For Profile size of 120 x 50 mm with 32 x 12 mm double rebate (Window Section) | rmt | ₹ 650 |
| 50.12 | Supply & Fixing of Rectified Porcelain Stoneware Tiles for Ventilated Facades of Specified size as per specification/ site drawings having 6 mm and 9 mm thickness with factorymade Kerfs (grooves) as per need and size 600/1200 and 800/1600. The Rectified Porcelain Stoneware Tiles shall possess properties having Water absorption < 0.5% Bending Strength > 40 N/mm2 and are resistant to: UV Light, chemicals, smog, thermal shocks & bacteria. The facade will be made from Nexion Rectified Porcelain Stoneware Tiles (Sintered Compact Surfaces) specified as per ISO 13006: Annex G- EN 14411: Annex G: Dry Pressed Ceramic Tiles and all the tests carried out by Italian labs accredited according to ISO/ IEC 17025: 2005.The Terramilano Fixing substructure will confirm to Norme Tec niche per le Costruzioni NTC/8 (Technical Standard for construction) guidelines for construction in Italy, Eurocode 0 "Information on the method of semi-probabilistic limit states and safety factor " Euro coad 1 " Determination and calculation of actions on structure " Euro 9 " Project aluminum structures " UNI 11018 and ETAG 034 The Substructure will consists of Upright extruded aluminum profile TruSt80, alloy6060 T5 thickness equal to 1.5 to 2 mm and dimension 80 x 110 mm, inter axis 80 cm of Length 3660 mm, 8085 Aluminum box Section of 1 x 3 inch,1x2inch and 1x 5 inch of length 3660 mm and thickness 1.5 to 2 mm as per need. Brackets St80 galvanized steel and aluminum of 80 mm x 60 mm, aluminum L bracket size 1.5 x 1.5 inch and 1 x 2.5 inch thickness 3 mm that allow to anchor the vertical stand to the Building, 9 mm/6mm S10 Hooks Harmonic Stainless Steel AISI 304 which supports the weight of the Tiles; Bossong/Hilti Mechanical Fasteners and Nylon Anchor Fastner; and Structural Sealant of 3M for Ventilated Facade. Packing of Edges and corner with window seal with ACP of appoved make for water Proofing and alteration. Inclusive of scaffolding and fixing. The installation method differ according to the structure of building and design. For EXTERNAL AND INTERNAL CLADDING OF STRUCTURE. with prior approval of concerned Superitending Engineer. | sqm | ₹ 8,694 |
| 50.13 | Supply & Fixing of Rock / Stone Finished outdoor vitrified flooring Tiles 20 mm thick and required width wide in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning complete. with prior approval of concerned Superitending Engineer. | sqm | ₹ 2,850 |
| 50.14 | Supply & Fixing of Rock / Stone Finished outdoor vitrified flooring Tiles 16 mm thick and required width wide in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning complete. with prior approval of concerned Superitending Engineer. | sqm | ₹ 2,650 |
| 50.15 | Supply & Fixing of Rock / Stone Finished outdoor vitrified flooring Tiles 16 mm thick and required width wide in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning complete with prior approval of concerned Superitending Engineer. | sqm | ₹ 2,550 |
| 50.16 | .Supply&Fixingof FullBodyVitrifid Steptiles Readytoinstall Treads and Risers 16 mm thick, required width and required finish in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning etc complete. with prior approval of concerned Superitending Engineer. | sqm | ₹ 2,850 |
| 50.17 | Supply&Fixingof FullBodyVitrifid Steptiles Readytoinstall Treads and Risers 12 mm thick, required width and required finish in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning etc complete. | sqm | ₹ 2,450 |
| 50.18 | Supply& Fixing of Rock/ Stone Finished FullBodyVitrifid Steptiles with thick Bullnose for Ready to install Treads and Risers, 16 mm thick and of required width in plain pattern includingCement float, fillingjoints, withneat cement slurry, Naturalsand, curing and cleaning complete. with prior approval of concerned Superitending Engineer. | sqm | ₹ 3,150 |
| 50.19 | Supply & Fixing of Rock/ Stone Finished Full Body Steptiles Stone Vitrifid Tiles with thick BullnoseforReadyto installSteps andRisers 12mm thick and requiredwidth wide in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning complete. with prior approval of concerned Superitending Engineer. | sqm | ₹ 2,650 |
| 50.20 | Providing hot dip galvanizing conforming to IS 12594-1988 to reinforcement bars, having mass of zinc coating shall not be less than 610 grm/ One Square Metre of bar surface area factory control process with Degreasing, Rinsing, Acid Pickling, Again Rinsing after picking, Fluxing, Hot Dip Galvanizing in molten Zinc bath Having Zinc purity of bath minimum 98.5% Quenching & Passivation Process. 32 mm to 40 mm dia. with prior approval of concerned Superitending Engineer. | MT | ₹ 15,513 |
| 50.21 | Providing hot dip galvanizing conforming to IS 12594-1988 to reinforcement bars, having mass of zinc coating shall not be less than 610 grm/ One Square Metre of bar surface area factory control process with Degreasing, Rinsing, Acid Pickling, Again Rinsing after picking, Fluxing, Hot Dip Galvanizing in molten Zinc bath Having Zinc purity of bath minimum 98.5% Quenching & Passivation Process. 16 to 25 mm dia with prior approval of concerned Superitending Engineer. | MT | ₹ 16,296 |
| 50.22 | Providing hot dip galvanizing conforming to IS 12594-1988 to reinforcement bars, having mass of zinc coating shall not be less than 610 grm/ One Square Metre of bar surface area factory control process with Degreasing, Rinsing, Acid Pickling, Again Rinsing after picking, Fluxing, Hot Dip Galvanizing in molten Zinc bath Having Zinc purity of bath minimum 98.5% Quenching & Passivation Process. 8 to 12 mm dia with prior approval of concerned Superitending Engineer. | MT | ₹ 16,941 |
| 50.23 | Providing and constructing non load bearing wall with 200 mm Horizontally perforated THERMO clayhollow blocks with compressive strengthnot less than 35Kilogram/Sqcm, U value of 0.60 W/m2K, Water Absorption of 15% mansonry to be done using sand cement mortar 1:6 with blocks of size 400mm x 200 mm x 200 mm (12.5 brick per One Square Metre. excluding mortar joint thickness) including cost of material, labour charges, scaffolding, curing at all height, complete as per specification & directions of Engineer in charge. Cost shall be inclusive of filling the blocks with cement mortar at exposed junctions andfillingwithconcreteusing12mmdownsizeaggregates at Windowand door Jambs for fixing hold fast.anchors etc. It must be green building certified from IGBC and Griha and Should comply IS code 3952 with prior approval of concerned Superitending Engineer. | sqm | ₹ 2,840 |
| 50.24 | Providing and constructing non load bearing wall with 150 mm Horizontally perforated THERMO clayhollow blocks with compressive strengthnot less than 35Kilogram/Sqcm, U value of 0.60 W/m2K, Water Absorption of 15% mansonry to be done using sand cement mortar 1:6 with blocks of size 400mm x 150 mm x 200 mm (12.5 brick per One Square Metre. excluding mortar joint thickness) including cost of material, labour charges, scaffolding, curing at all height, complete as per specification & directions of Engineer in charge. Cost shall be inclusive of filling the blocks with cement mortar at exposed junctions andfillingwithconcreteusing12mmdownsizeaggregates at Windowand door Jambs for fixing hold fast.anchors etc. It must be green building certified from IGBC and Griha and Should comply IS code 3952 with prior approval of concerned Superitending Engineer. | sqm | ₹ 2,750 |
| 50.25 | Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer. | sqm | ₹ 10,590 |
| 50.26 | Providing and constructing non load bearing wall with 200 mm Grinded Horizontally perforated clayhollow blocks with compressive strength not less than 35Kilogram/Sqcm, U value of 1.00 W/m2K, Water Absorption of 15% tolerance on Grinded brick height is +/- 1.00 mm, masonry to be done using POROTHERM Dry Flx. Systeam with 20 mm thick S shape application (Application method need to be followed as per Wienerberger methodology) blocks of size 400mm x 200 mm x 200 mm (12.5 brick per One Square Metre.) including cost of material, labour charges, scaffolding, curing at all height, complete as per specification & directions of Engineer in charge. Cost shall be inclusive of end bricks to be used at window and door jambs for fixing hold fast. anchors etc.,plastering is to be done as per requirement.and is to be considered seperatly with prior approval of concerned Superitending Engineer. | sqm | ₹ 1,822 |
| 50.27 | Providing and constructing non load bearing wall with 150 mm Grinded Horizontally perforated clayhollow blocks with compressive strength not less than 35Kilogram/Sqcm, U value of 1.2 W/m2K, WaterAbsorption of15% toleranceon Grindedbrick height is+/- 1.00 mm, masonry to be done using Dry Flx. Systeam with 20 mm thick S shape application (Application method need to be followed as per Wienerberger methodology) blocks of size 400mm x 150 mm x 200 mm (12.5 brick per One Square Metre.) including cost of material, labour charges, scaffolding, curing at all height, complete as per specification & directions of Engineer in charge. Cost shall be inclusive of end bricks to be used at window and door jambs for fixing hold fast. anchors etc.,plastering is to be done as per requirement and is to be considered seperatly | sqm | ₹ 1,650 |
| 50.28 | Providing and constructing non load bearing wall with 100 mm Grinded Horizontally perforated clayhollow blocks with compressive strength not less than 35Kilogram/Sqcm, U value of 1.7 W/m2K, Water Absorption of 15% tolerance on Grinded brick height is +/- 1.00 mm, masonry to be done using Dry Flx. Systeam with 20 mm thick S shape application (Application method need to be followed as per Wienerberger methodology) blocks of size 400mm x 100 mm x 200 mm (12.5 brick per One Square Metre.) including cost of material, labour charges, scaffolding, curing at all height, RCC. stiffener band necessary at every1.0 meter height of the wall, complete as per specification & directions of Engineer in charge. Cost shall be inclusive of end bricks to be used at window and door jambs for fixing hold fast. anchors etc.,,plastering is to be done as per requirement,and is to be considered seperatly with prior approval of concerned Superitending Engineer. | sqm | ₹ 1,325 |
| 50.29 | Providing and fixing of imported clay tiles pn M.S. frame Work using Maditerranean plus roof tiles of Wienberger tile of colour Red Engobe or equivalent with necessary accessories required to fix tile including clips and screw (Prior permission of S.E. is to be obtained before inclusion) | sqm | ₹ 3,062 |
| 50.30 | Providing and fixing Ductile iron manhole cover of light/medium/heavy duty with frame of any size over inspection chamber etc. complete (Prior permission of S.E. is to be obtained before inclusion of this item in the estimate) | kg | ₹ 75 |
| 50.31 | Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concretebedding15cmthick burnt brickmansonrywith1:1 cement mortar plaster25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125Kilogramin weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer. | nos | ₹ 12,000 |
| 50.32 | Providing and laying CE Marked Woven Polypropylene Geotextile indigenously manufactured from black UV stabilized polypropylene tape yarn of Techfab India on the prepared subgrade for Reinforcement cum separation cum drainage & filtration application with necessaryoverlaps asper drawingetc. complete. (Specification: MORTH Section-700) with prior approval of concerned Superitending Engineer. a)TFI-5300 Type-I | sqm | ₹ 160 |
| 50.33 | Providing and laying CE Marked Woven Multifilament Polyester Geotextile indigenously manufactured using high molecular weight, high tenacity polyester filament yarn with high tensile strength, low elongation and low creep of Techfab India on the prepared subgrade for Reinforcement cum separation cum drainage & filtration application with necessary overlap as per drawing etc. complete. (Specification: MORTH Section-700) with prior approval of concerned Superitending Engineer. | ||
| 50.33a | TFI-3100 | sqm | ₹ 160 |
| 50.33b | TFI-3200 | sqm | ₹ 224 |
| 50.34 | Providing and laying CE Marked Needle Punched and Mechanically Bonded Non-Woven Geotextile (TechGeo) indigenously manufactured from high quality polypropylene staple fibres (continuous filament will not be accepted) of Techfab India on the prepared subgrade for separation, drainage & filtration application with necessary overlaps as per drawing etc. complete. (Specification: MORTH Section-700) with prior approval of concerned Superitending Engineer. | ||
| 50.34a | TFI TECHGEO PR-15 | sqm | ₹ 134 |
| 50.34b | TFI TECHGEO PR-20 | sqm | ₹ 151 |
| 50.34c | TFI TECHGEO PR-30 | sqm | ₹ 167 |
| 50.34d | TFI TECHGEO PR-40 | sqm | ₹ 207 |
| 50.34e | TFI TECHGEO PR-60 | sqm | ₹ 279 |
| 50.35 | Providing and Laying CE marked Knitted and PVC coated Polyester Biaxial Geogrid (Techgrid) for Basal Reinforcement indigenously manufactured from selected high tenacitypolyester yarn with high molecular weight of Techfab India (> 25000 g/mol), and lowcarboxylendgroup(<30mmol/Kilogram) (extrudedPP geogrids & Polyesterstrips & Geostrips, Steel Strips not allowed & not accepted). Requirement of geogrid strength in both direction and granular fill. (Coating of Geogrid/ reinforcing geosynthetic material with LDPE, approved, Bitumen and anyother coating will not be allowed and will not be accepted). For reinforcement application to subgrade, unbound sub base / base courses & soil stabilization, etc. complete (Specification: MORTH Section-700). with prior approval of concerned Superitending Engineer. | ||
| 50.35a | TFI TechGrid GeoGrid TGB-40 | sqm | ₹ 199 |
| 50.35b | TFI TechGrid GeoGrid TGB-60 | sqm | ₹ 240 |
| 50.36 | Providing and laying CE Marked PP Extruded Biaxial Geogrid for basal reinforcement, indigenously manufactured from virgin high density polypropylene of Techfab India having aperture size of (38 x 38)mm and ultimate tensile strength of 20 kN/m on both direction with minimum junction strength of 95% & minimum radial stiffness of 350 kN/m (@0.5% strain for reinforcement application to subgrade, unbound sub base / base courses & soil stabilization, etc. complete (Specification: MORTH Section-700).with prior approval of concerned Superitending Engineer. | ||
| 50.36a | TFI TechGrid GeoGrid PP2020 | sqm | ₹ 230 |
| 50.36b | TFI TechGrid GeoGrid PP3030 | sqm | ₹ 296 |
| 50.37 | Providing and laying CE Marked knitted and PVC coated Polyester Uniaxial Geogrid (Techgrid) indigenously manufactured from selected high tenacity polyester yarn with high molecular weight of Techfab India (> 25000 g/mol), and low carboxyl end group (<30 mm mol /Kilogram) (extruded PP geogrid & Polyester strip & Geostrip, steel strips not allowed & not accepted) with granular fill as per design prepared by technical provider of reinforced earth wall and slope. The reinforced earth wall and slope should have 100% coverage of 5m width knitted and PVC coated Polyester geogrid. (Coating of Geogrid/Reinforcing geosynthetic material with LDPE, approved, Bitumen and any other coating will not be allowed and will not be accepted) for reinforced soil wall and reinforced slope application, etc. complete (Specification: MORTH Section-3100).with prior approval of concerned Superitending Engineer. | ||
| 50.37a | TFI TechGrid GeoGrid TGU-40 | sqm | ₹ 181 |
| 50.37b | TFI TechGrid GeoGrid TGU-60 | sqm | ₹ 202 |
| 50.38 | Providing and laying Geocell-Techcell CE Marked a three dimensional honeycomb like cellular confinement system having weld spacing 356mm and cell depth 150mm of Techfab India, indigenouslymanufactured byblend of various polyethylene and additives, polyethylene strips ultrasonically welded consists of a multiple rhomboidal indentations over the entire strip on the prepared subgrade for subgrade stabilization by reinforcement and drainage application for roads, ground improvement work and erosion control of slopes etc. complete. (Specification: MORTH Section-700) with prior approval of concerned Superitending Engineer. | ||
| 50.38a | TFI TechCell GeoCell-356x150 | sqm | ₹ 560 |
| 50.38b | TFI TechCell GeoCell-660x75 | sqm | ₹ 326 |
| 50.39 | Providing and laying CE Marked Reinforced Non-Woven Composite indigenously manufactured needle punched polypropylene (continuous filament will not be accepted) of Techfab India, Reinforced with high tenacityPolyester Yarn onthe preparedsub grade for Reinforcement cum separation cum drainage & filtration application with necessary overlaps as per drawing etc. complete. (Specification: IRC:SP:59-MORTH Section-700) with prior approval of concerned Superitending Engineer. | ||
| 50.39a | TFI TGC-60 | sqm | ₹ 207 |
| 50.39b | TFI TGC-90 | sqm | ₹ 252 |
| 50.40 | Providing and inserting CE Marked Prefabricated Vertical Drain / Band Drain (TechDrain) of Techfab India indigenously manufactured with Polypropylene Core and wrapped with Non-Woven Geotextile in the very soft clay to a design depth for quick consolidation etc. complete. (Specification: MORTH Section-700).with prior approval of concerned Superitending Engineer. | ||
| 50.40a | TFI TechDrain TD-3520 U 100mm x 4mm | rmt | ₹ 73 |
| 50.40b | TFI TechDrain TD-5020 U 100mm x 5mm | rmt | ₹ 87 |
| 50.41 | Providing & fixing CE Marked Metal Gabions indigenouslymanufactured as per required section including boxes made of mechanically woven hexagonal shaped wire mesh of type, (8 x 10)cm, edgesmechanicallyselvedgedmade ofheavily(Zinc+ PVC)coated G.I. wires as per BS:443, mesh wire 2.70/3.70 mm Ø (ID/OD), edge wire 3.40/4.40 mm Ø (ID/OD) of Techfab India type and filled with 20 to 50Kilogramweight trap stones including conveying with all leads and lifts and placing at required places in required line, level, slope, section as directed, etc. and tied by5% lacing wire 2.20/3.20 mm Ø (ID/OD) as directed by Engineer-in-charge. For retaining walls, toe walls, etc. for slope protection & erosion control application of river bank & sea-shore etc. complete (Specification: MORTH section-2500. (Excluding Rubble) with prior approval of concerned Superitending Engineer. | ||
| 50.41a | For 1m height | cum | ₹ 1,953 |
| 50.41b | For 0.5m height | cum | ₹ 2,280 |
| 50.42 | Providing and laying CE Marked Glassfibre GeoComposite (TechGlass AIC) indigenously manufactured from high performance glass fibre roving to form a reticular structural material with a unique combination of fused fibre glass and polypropylene non- woven needle punched geotextile to asphalt overlay flexible pavements and asphalt overlay distressed rigid pavements of Techfab India for Reinforcement, seizure reflective cracks, reduced surface rutting & water infiltration. (Specification: MoRTH section- 700).with prior approval of concerned Superitending Engineer. | ||
| 50.42a | TFI Techglass AIC-50 | sqm | ₹ 240 |
| 50.42b | TFI Techglass AIC-100 | sqm | ₹ 268 |
| 50.43 | Providing and laying a Paving Fabric CE Marked Needle Punched and Mechanically Bonded Non-Woven Geotextile of Techfab India, indigenously manufactured from high quality polypropylene staple fibres (continuous filament will not be accepted) with heat treatment on one side to form a strong, flexible and dimentionaly stable fabric structure, with optimum bitumen retention capacity to asphalt overlay over flexible pavement and distresses regid pcc pavement for moisture barrier, avoid refelective cracking and stress relieving membrane with necessaryoverlaps as per drawing, etc. complete. (Specification: MORTH section-700). with prior approval of concerned Superitending Engineer. | ||
| 50.43a | TFI TechPave-C040 | sqm | ₹ 116 |
| 50.44 | Providing and laying Fin Drains (Drainage Composite) TFI TDC-55130W CE Marked indigenously manufactured by thermo bonding a polypropylene drainage core- Geonet comprises of two sets of parallel overlaid ribs integrally connected to have a rhomboidal shape and Needle Punched & Thermally Bonded Nonwoven Geotextile on the prepared sub base of paved/unpaved roads & behind the RE wall byreplacing granular filter media for separation, drainage & filtration application with necessary overlaps as per drawing etc. complete. (Specification: MORTH Section-700) with prior approval of concerned Superitending Engineer. | ||
| 50.44a | TFI TDC-55130W | sqm | ₹ 431 |
| 50.45 | Construction of Reinforced Earth Wall in M-35 Block Facia byProviding and Laying CE marked Knitted and PVC coated Polyester Uniaxial Geogrid (Techgrid) of Techfab India indegeniously manufactured from selected high tenacity polyester yarn with high molecular weight (> 25000 g/mol), and low carboxyl end group (<30mmol/Kilogram) for Reinforced soil wall (extruded PP geogrids & Polyester strips & Geostrips, Steel Strips not allowed & not accepted) with granular fill of PHi-32 degree (design is to be carried out in accordance with BS-8006 / FHWA) with concrete block by M-35 as facia, casting & erection of blocks with Techgrid, providing & laying levelling pad byM-15, providing and laying coping beam by M-35, providing and laying 300mm thick filtermedia etc. completed as per necessary drawing and instruction of Engineer-in-charge. Excluding providing, laying and compacting selected backfill and retained fill behind the wall, excavation and ground improvement, if any. The reinforced earth wall and slope should have 100% coverage of 5m width Knitted and PVC coated Polyester Geogrid. (Coating of Geogrid/ Reinforcing geosynthetic material with LDPE, approved, Bitumen and anyother coating will not be allowed and will not be accepted). (Specification: MORTH Section- 3100) with prior approval of concerned Superitending Engineer. | ||
| 50.45a | RE Wall Height 1 to 4 meter | sqm | ₹ 5,486 |
| 50.45b | RE Wall Height 4 to 6 meter | sqm | ₹ 5,832 |
| 50.45c | RE Wall Height 6 to 8 meter | sqm | ₹ 6,085 |
| 50.45d | RE Wall Height 8 to 10 meter | sqm | ₹ 6,313 |
| 50.45e | RE Wall Height 10 to 12 meter | sqm | ₹ 6,831 |
| 50.45f | RE Wall Height 12 to 14 meter | sqm | ₹ 7,285 |
| 50.46 | Providing Heavy Duty Fibre Glass Reinforced Plastic Temporary Barricade of 1.75 m hight, with base width of 430 mm as a provision to accept water ballasting of101 Itrs-110 Ltrs approx. and arrangement for traffic diversion such as traffic signals during construction at site, for day and night as per requirement. The raw material shall be UV stabilized Linear Low Density Polyethylene and should meet the requirements stipulated in standard IS: 10146-1982, IS:10141-1982 and should also comply to FDA:CFR Title 21.177.1520. Olefin Polymers, with specific FRP Grade 300-104 reinforced during moulding process to the permissible extent for improved impact strength. Qualification Criteria: For qualifying the sample, few tests shall be performed at Government Lab OR NABL Accredited Lab on Site Safety Fence sample, failure or deviations in test results of sample shall be disqualified.The tests and qualifying results are as under, (a) tensile strength at yield by ASTM D 638 =20.93 mPA, (b) Elongation at break ASTM D 638 = 121.66 mPA (c) Flexural Modulus ASTM D 790 = 633.76 mPA (d) Izod Impact Strenth (Notched) ASTM D 256 = 4.41Kilogram/ One Square Metre (e) Izod Impact Strenth (Un- Notched) ASTM D 256 = 67.04Kilogram/ One Square Metre (f) Drop Impact strength 25KilogramLoad from 1 m, 2 m & 5m height the weight of empty single Rotomoulded Plastic Barricade without water ballasting shall be 34 Kilograms approx. & total weight after water allasting shall be 135 Kilograms -140 Kilograms +/- 5 Kilograms (tolarance)The main Barricade body of hight 1750 mm approx is connected with the Extension body through 4 set of nut bolt washers.extenstion body through 4 set of nut bolt washers. Extension bodyis designedwith 9Nos kiss offs onrear side; the dimension of Extension body are 1500 mm (length),70 mm (width),250 mm (effetive height after fixing) & dimension of its male collarare 1420 mm (length),25 mm (width),30 mm approx ( height), it is inserted in U groove provisioned on top of main body Barricade Model for interlconnecting.the minimum thickness of all over surface of plastic barricaed shall be 5 mm +/- 20%.the rear bottam shall have to provision to fix two brackets at both end in corner for anchoring purpose.each rear bracket is constructed through rod of Dia.60 mm with curvature welded with MS strip of 3 mm thick,50 mm width and 90 mm length at its top and base,effective bracket shall be 410 mm approx. the anchoring | ||
| 50.46a | hole a) For in each 725 bracket mm height shall be (LType 18 mm dia. Jersey for routine Barrier the) MS,Empty bolts Weight:6.67 of 16 mm thickness Kilogram/ and Rgm,Weight Full: 35.89Kilogram/ Rgm approx. (After Water / Sand Filling) | rmt | ₹ 1,846 |
| 50.46b | For 750 mm height (With Interlocking provison -For Traffic Delineation Applications), Empty Weight:9.04 Kilogram/ Rgm,Weight Full: 57.14Kilogram/ Rgm approx. (After Water / Sand Filling) | rmt | ₹ 2,872 |
| 50.46c | For 750 mm height ( Jersey Barrier Model with unique Interlocking Provision), Empty Weight:9.0 Kilogram/ Rgm,Weight Full: 55.00Kilogram/ Rgm approx. (After Water / Sand Filling) | rmt | ₹ 5,026 |
| 50.46d | Site Safety Fence (1.75 Mtrs(H)) (Efficient Substitution to sheet Metal Barricade), Empty Weight 16.57: Kilogram/ Rgm,Weight Full: 74.29 Kilogram/ Rgm approx. (After Water / Sand Filling) | rmt | ₹ 8,103 |
| 50.46e | Site Safety Fence (2.00 Mtrs(H)) (Efficient Substitution to sheet Metal Barricade), EmptyWeight: 17.00 Kilogram/ Rgm,Weight Full: 70.00 Kilogram/ Rgm approx. (After Water / Sand Filling) | rmt | ₹ 8,718 |
| 50.47 | organosilance Nanotechnology for Bituminous organosilance nanotechnology such as Zycotherm added in the bitumen binder @ 0.1% dosage to the weight of the bitumen at HMA plant to schive chemical bonding,complete coating and consistant compaction in various bituminous mixes such as BM/DBM/Carpet/sealcoat/MSS/SDBC etc.as per the direction of Engineer-in-charge with prior approval of concerned Superitending Engineer. | kg | ₹ 1,400 |
| 50.48 | Water proofing of subgrade:waterproofing on top compacted (as per relevant MORT&H specification)sub grade and shoulder soil base with organosilance Nanotechonology & nano acrylic co-polymer with water (<1000 ppm TDS)in the ratio of 1KilogramOrganosilance Nanotechonology:1Kilogramnano acrylic co-polymer:200 liter water spray @3 liter/ One Square Metre in two spray application (1.5 liter +1.5 liter) as per direction of the Engineer-in-charge. with prior approval of concerned Superitending Engineer. | sqm | ₹ 15 |
| 50.49 | providing and applying primer coat with bitumen emulsion on prepared surface of Aggregate layer including clearing of road surface and spraying primer mixed with Nano- Technology silance in the ratio 1:100:100 (1Kilogramsilance:100KilogramSS1 Emulsion:100 liter water);the rate of 1 Liter/ One Square Metre using mechanical means asperthe direction of Engineer-in-charge. with priorapproval ofconcerned Superitending Engineer. | sqm | ₹ 18 |
| 50.50 | Tack coat (with Silance nanotechnology):preparing and applying of water soluable organo silance nanotechnology (for bitumen emulsion application,IRC approved) with cationic bitumen emulsion CRS1 amd water (< 1000 ppm TDS) in the ratio of 1:4Kilogram organo silance: 100Kilogram cationic bitumen emulsion CRSS1: 200 liter water. with prior approval of concerned Superitending Engineer. | sqm | ₹ 8 |
| 50.51 | Construction of stabilised soil base with organo silance by providing locally available moorum/soil(70%) mixed with 30% GSB ॥ with 2% cement by MDD of mix, 0.6 Kilogram/Cum nanotechnology silane & 0.6 Kilogram/ cum of Acrilic Nano - Co polymer, Spreading in uniform layers with grader on prepared surface by mixing in place method withrotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Table 2.3 of IRC SP - 77-2008 as per direcion of Engineer - in -charge. with prior approval of concerned Superitending Engineer. | cum | ₹ 1,613 |
| 50.52 | Construction of stabilised soil base with organo silance by providing locally available moorum/soil(70%) mixed with 30% GSB ॥ with 3% cement by MDD of mix, 0.6 Kilogram/Cum nanotechnology silane & 0.6 Kilogram/ cum of Acrilic Nano - Co polymer, Spreading in uniform layers with grader on prepared surface by mixing in place method withrotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Table 2.3 of IRC SP - 77-2008 as per direcion of Engineer - in -charge.with prior approval of concerned Superitending Engineer. | cum | ₹ 1,701 |
| 50.53 | Construction of stabilised soil base with organo silance by providing locally available moorum/soil(70%) mixed with 30% GSB ॥ with 4% cement by MDD of mix, 0.6 Kilogram/Cum nanotechnology silane & 0.6 Kilogram/ cum of Acrilic Nano - Co polymer, Spreading in uniform layers with grader on prepared surface by mixing in place method withrotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Table 2.3 of IRC SP - 77-2008 as per direcion of Engineer - in -charge. | cum | ₹ 1,789 |
| 50.54 | Supplying trap/granite/quartzite/gneiss stone metal of required size by bringing the boulders / Rubble at the road side breaking them to required gradation including conveying the boulders /Rubble and stacking the broken metal etc. complete. (Prior approval of sample stack of broken metal by the Ex. Engineer is necessary the date of approval will form part of the measurements) a)80 mm Metal, By breaking rubble obtained by blasting.(Hand broken). with prior approval of concerned Superitending Engineer. | cum | ₹ 730 |
| 50.55 | Supplying trap/granite/quartzite/gneiss stone metal of required size by bringing the boulders / Rubble at the road side breaking them to required gradation including conveying the boulders /Rubble and stacking the broken metal etc. complete. (Prior approval of sample stack of broken metal by the Ex. Engineer is necessary the date of approval will form part of the measurements) a)40 mm Metal, By breaking rubble obtained by blasting.(Hand broken). | cum | ₹ 780 |
| 50.56 | Supplying trap/granite/quartzite/gneiss stone metal of required size by bringing the boulders / Rubble at the road side breaking them to required gradation including conveying the boulders /Rubble and stacking the broken metal etc. complete. (Prior approval of sample stack of broken metal by the Ex. Engineer is necessary the date of approval will form part of the measurements) a)80 mm Metal, By breaking Boulders (Hand broken). | cum | ₹ 700 |
| 50.57 | Supplying trap/granite/quartzite/gneiss stone metal of required size by bringing the boulders / Rubble at the road side breaking them to required gradation including conveying the boulders /Rubble and stacking the broken metal etc. complete. (Prior approval of sample stack of broken metal by the Ex. Engineer is necessary the date of approval will form part of the measurements) a)40 mm Metal, By breaking Boulders (Hand broken). | cum | ₹ 750 |
| 50.58 | Spreading 80/40 mm metal for road work including sectionong etc complete as directed by Engineer in charge. | cum | ₹ 85 |
| 50.59 | Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Power roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete. (cid:10) | sqm | ₹ 27 |
| 50.60 | Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Vibratory roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete. (cid:10) | sqm | ₹ 37 |
| 50.61 | Compacting the sub grade / gravel / size metal (100 mm loose) layers for all widths with Power roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete. (cid:10) | sqm | ₹ 25 |
| 50.62 | Compacting the sub grade / gravel / size metal (100 mm loose) layers for all widths with vibratory roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete. (cid:10) | sqm | ₹ 34 |
| 50.79 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. | sqm | ₹ 372 |
| 50.80 | Supplyof readymix patch repairing compound as per section 3000.2.2(filling pothole and patches repair with specific approval of the engineer),MORT&H specifications for roads and bridge works,5th Revision, for instant repair of surface defects of road under all weather conditions.The premix should consists of a binder with hydrophilic properties and accelerated adherence to all types of aggregares and can be applied on all patches and potholes including water logged patches and poyholes and in rainy conditions. The material should be suitable for both Bituminous and concrete roads with quick setting properties and allow traffic to be released within 10 mins.of patch or pothole repair.the material should for use on roads with both passanger and heavy commercial vechiles.The mix should be suitable for reparing of surfacing course and should be comparising of fine aggregates 0-10 mm,(5.5-7.5 %).additives as ewquired.the mix should packed in bags which can be easilyhandled manuallyand be storable under normal storage conditions for at least 8 month. | kg | ₹ 25 |
| 50.81 | Fire Door 45mm 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. | ||
| 50.81a | Door Frame: Supplying frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 60 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete. | rmt | ₹ 1,569 |
| 50.81b | Shutter: Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kilograms/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. | sqm | ₹ 9,014 |
| 50.81c | Vision Panel: 1 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside theshutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. With clear fire resistant glass panes 11mm thick having minimum 120 minutes fire Description | sqm | ₹ 33,475 |
| 50.82 | Providing of Accoustic Door to effectively control noise inconference rooms, broadcasting studios, theatres and music practice rooms. with prior approval of concerned Superitending Engineer. | ||
| 50.82a | Door Frame: Providing Frames for Accoustic door shutters with double rabbit of 68mm 1st class Malaysian Hardwood Frame densified and pressure treated with chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm sprayquoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Hafele Accoustic seals concealed in the groove of the Frame for noise control, etc. complete as per direction of Engineer in Charge | rmt | ₹ 1,936 |
| 50.82b | Shutter: Providing of 65mm thick Accoustic Door Shutters with wooden structure comprising of Chemical treated internal timber with anti termite chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x 48 mm with 48 mm thick infill of ceramic vermiculite mix of density 54Kilograms/CMT, 3mm sheet rubber interlayer sheet on one side for acoustic property, faced with 6mm High DensityWaterproof Plyconfirming to IS Code 2201, internallylipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of PU paint of minimum 200 micron of color of engineer choice (any Veneer or Lamination will cost extra), without any external lipping along with double rebatting in shutters & accoustic seal | sqm | ₹ 13,650 |
| 50.83 | 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. with prior approval of concerned Superitending Engineer Providing of 120 min Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 &22 1987 toachieve therequired integrity, insulation andstability(i.e.to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). Lead lined to check radiation. Code No; 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. | ||
| 50.83a | Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisturebelow15%asperIS:1141ofsection 140X70mmwith45mm thick two layered 3mm Lead Line Sheets with 10mm overlap from either side & spray quoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mmconcealed inthe grooveof theFrame for fire and hot and cold smoke sealing, etc. complete as per direction of Engineer in Charge | rmt | ₹ 3,033 |
| 50.83b | Shutter: Providing of 57mm thick asbestos free composite, 'TUFWUD' brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x30 mm with 30mm thick infill of ceramic fibre (density 128 Kilograms/CMT) vermiculite mix, 3mm thick Lead Sheet on one side faced & 3mm Fire retardant High Density Fibreboard, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of Intumescent paint of minimum 300 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. | sqm | ₹ 20,690 |
| 50.84 | Providing of Lead Lined Door system with 120x60 mm Hardwood Frames, interlayered with 3mm lead and 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type), interlayered with 3mm lead with prior approval of concerned Superitending Engineer. | ||
| 50.84a | Door Frame: Providing Frames for Lead Lined door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets being overlapped from either side, sprayquoted with 2 coats of Enamel paint after one coat of white wood primer of minimum 200 micron etc. complete as per direction of Engineer in Charge. with prior approval of concerned Superitending Engineer. | rmt | ₹ 2,575 |
| 50.84b | Shutter: Supplying of ' 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type). 32mm Wooden structure of 1st class Hardwood or Pinewood of at least 50mm width, top and bottom rails of 75mm width, with filler material without any gap of 1st Class Hardwood, or pine wood, all chemically treated for termite and borer resistance as per IS 401:2001 under minimum 150 PSI pressure, and seasoned as per IS 1141: 1993 upto desired moisture level as per IS 287, with one side 3mm HDF & other side 3mm lead & 6mm BWP ply; all hot-pressed with Phenol Formaldehyde resin, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of enamel paint of minimum 300 micron. with prior approval of concerned Superitending Engineer. | sqm | ₹ 17,126 |
| 50.85 | Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer. | kg | ₹ 288 |
| 50.86 | Supplying installation testing and commissoning of Hubless centrifugally cast iron pipes as per ISI 15905 equivalent to NECO inclusive of all necessary special fitting like bends, tees, and caps, 'Y' bends for cleaning offsets, junctions, cowls, etc. lad under floor/fixed on walls and in pipe shafts etc. complete. The quoted rate should include lead and lifting charges to all levels, necessary scaffolding and supports like hanger supports grip bolts and CV sheet 304 grade clamps etc. with prior approval of concerned Superitending Engineer. | ||
| 50.86a | 50 mm dia | rmt | ₹ 1,657 |
| 50.86b | 65 mm dia | rmt | ₹ 1,841 |
| 50.86c | 75 mm dia | rmt | ₹ 1,964 |
| 50.86d | 100 mm dia | rmt | ₹ 2,256 |
| 50.86e | 150 mm dia | rmt | ₹ 4,259 |
| 50.86f | 200 mm dia | rmt | ₹ 6,787 |
| 50.86e | 250 mm dia | rmt | ₹ 7,538 |
| 50.86f | 300 mm dia | rmt | ₹ 9,659 |
Source: State Schedule of Rates 2022-23, Public Works Department, Government of Maharashtra — completed rates excluding GST. Rates are shown as published; check the official book and its correction slips before you submit an estimate. BESTimate is not issued by or affiliated with this department.